0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Experimental Study on Seismic Performance Evaluation of a Multi-Story Steel Building Model with Rolling-Type Seismic Base Isolation

Auteur(s): ORCID
ORCID

Médium: article de revue
Langue(s): anglais
Publié dans: Buildings, , n. 10, v. 14
Page(s): 3268
DOI: 10.3390/buildings14103268
Abstrait:

Critical structures such as hospitals, high-precision manufacturing facilities, telecommunications centers, and fire stations, especially, need to maintain their functionality even during severe earthquakes. In this sense, seismic isolation technology serves as a vital design method for preserving their functionality. Seismic isolators, also known as earthquake isolation systems, are used to reduce the effects of earthquakes on buildings by isolating them from the ground they are located on. By ensuring that less acceleration and force demand is transmitted to the superstructure, both the building and the equipment and the devices in the building are prevented from being damaged by earthquakes. This experimental study aims to conduct vibration tests on a small-scale multi-story steel-building model equipped with a specially designed rolling-type seismic base isolation system. The relationship between the test model and the prototype was achieved by frequency simulation. The tests will be performed on a shake table under six different earthquake accelerations to examine the model’s dynamic behavior. The primary goal is to evaluate the isolation performance of the rolling-type seismic base isolator under seismic loads, with a focus on recording the vibrations at the top of the test building. It has been observed that the isolator placed at the base of the building significantly reduced the peak acceleration and displacement values of the floor motion. Under the most severe earthquake record applied to the shake table, the acceleration at the top of the building with the isolator was found to be reduced by approximately 50%, compared to the non-isolated case.

Copyright: © 2024 by the authors; licensee MDPI, Basel, Switzerland.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10804812
  • Publié(e) le:
    10.11.2024
  • Modifié(e) le:
    10.11.2024
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine