0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Experimental Study on Electric Resistivity Characteristics of Compacted Loess under Different Loads and Drying-Wetting Cycles

Auteur(s):








Médium: article de revue
Langue(s): anglais
Publié dans: Advances in Civil Engineering, , v. 2021
Page(s): 1-12
DOI: 10.1155/2021/6672430
Abstrait:

Densely compacted loess foundations of many man-made infrastructures are often exposed to various loads and extreme weathering processes (e.g., drying-wetting cycles), which significantly deteriorate their mechanical properties. Traditional methods applied to characterize soil engineering properties are primarily based on visual inspections, point sensors, or destructive approaches, the results of which often have relatively high costs and cannot provide large-area coverage. The electrical resistivity method is a reasonable alternative that provides a nondestructive, sensitive, and continuous evaluation of the soil physical properties. Thus, the relationships between electrical resistivity and soil strength should be understood, particularly for scenarios in which soils undergo significant loads and cycles of drying and wetting. In this study, a suite of laboratory tests simulating loads (consolidation tests, unconfined compression tests, and uniaxial cyclic unloading-reloading tests) and seasonal field conditions (drying-wetting cycle tests) were conducted to quantitatively assess their deterioration effects on the geophysical and geotechnical properties of compacted loess. The experimental results indicated that electric resistivity decreases with the increase in stress and then approaches a stable value after the stress becomes 200 kPa. During the uniaxial compression process, the electric resistivity corresponds to both the stress and strain of loess in real-time. The electrical resistivity of loess reflects plastic damage under uniaxial unloading-reloading tests, but it is deficient in representing the dissipated energy of loess. The electrical resistivity of loess samples increases as the number of drying-wetting cycles increases but decreases with increasing cycle numbers after stabilization under consolidation load. The electrical resistivity can effectively characterize the mechanical and deformation characteristics of loess samples under loads and drying-wetting cycles, exhibiting a certain potential for long-term monitoring of soil engineering properties.

Copyright: © Yu Zhou et al.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10560632
  • Publié(e) le:
    03.02.2021
  • Modifié(e) le:
    02.06.2021
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine