0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Experimental Study on Effects of Type and Replacement Ratio of Fly Ash on Strength and Durability of Concrete

Auteur(s):
Médium: article de revue
Langue(s): anglais
Publié dans: The Open Civil Engineering Journal, , n. 1, v. 7
Page(s): 93-100
DOI: 10.2174/1874149520130708004
Abstrait:

This paper presents the test results of a series of experimental studies on the effects of type and replacement ratio of fly ash on strength and durability of concrete. 3 types of fly ashes are used in this research, the specific surface area of which are 5070 cm²/g, 3760 cm²/g and 1970 cm²/g, respectively. They satisfy the requirement of Type-1, Type-2 and Type-4 fly ashes in Japanese Industrial Standard. Ordinary Portland cement, river sand, crushed sandstone, water reducer and air entraining agent are used as well. The results indicate that drying shrinkage of concrete is reduced when cement is partially replaced by fly ash. Comparatively, Type-2 fly ash's addition leads to a more effective drying shrinkage reduction, and those with replacement ratios result in larger dry shrinkage reduction. Carbonation increases with the increase of replacement ratio of fly ash, and concrete with Type-1 fly ash has higher carbonation than those with Type-2 and Type-4 fly ashes. The carbonation rate is found to be linear with water cement ratio regardless of replacement ratio of fly ash. Durability factor decreases with the replacement ratio of fly ash after 300 freezing and thawing cycles. Also, durability factor of concrete containing Type-1 and Type-2 fly ashes with replacement ratio of 25% to 55% is higher than 80%. However, those with Type-4 fly ash show lower durability factor after 300 cycles. Concretes with 70% replacement of fly ash are not durable in spite of the type of fly ash or specific surface area.

Copyright: © 2013 Hongzhu Quan
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10175790
  • Publié(e) le:
    02.01.2019
  • Modifié(e) le:
    02.06.2021
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine