Experimental Investigations on Punching Shear of Flat Slabs Made from Lightweight Aggregate Concrete
Auteur(s): |
M. Gołdyn
Ł. Krawczyk W. Ryżyński T. Urban |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Archives of Civil Engineering, décembre 2018, n. 4, v. 64 |
Page(s): | 293-306 |
DOI: | 10.2478/ace-2018-0058 |
Abstrait: |
In the paper the results of experimental investigations concerning flat slabs made from reinforced lightweight concrete with sintered fly ash aggregate CERTYD were presented. In the research program 6 models made in a natural scale were included. The main variable parameter was slab longitudinal reinforcement ratio. The aim of investigation was the experimental verification of efficiency of double-headed studs as punching shear reinforcement. In the existing technical approvals such kind of reinforcement was allowed only in normal concrete slabs. It was demonstrated that double-headed studs can be an effective transverse reinforcement of lightweight aggregate concrete slabs. The use of double-headed studs resulted in increase in the ultimate load from 19% to 44%, depending on the slab reinforcement ratio which ranged from 0.5% to 1.2%. The comparative analysis showed that the Eurocode 2 provisions were conservative in relation to the experimental results, which were on average 42% higher than the theoretical ones however with a very low 7% coefficient of variation. |
- Informations
sur cette fiche - Reference-ID
10476703 - Publié(e) le:
25.11.2020 - Modifié(e) le:
25.11.2020