Evaluation of a Four-Story Reinforccd Concrete Building Damaged during the Northridge Earthquake

Auteur(s):

Médium: article de revue
Langue(s): anglais
Publié dans: Earthquake Spectra, , n. 3, v. 13
Page(s): 387-414
DOI: 10.1193/1.1585954
Abstrait:

A four-story reinforced concrete (RC) frame structure damaged during the Northridge Earthquake was evaluated to determine if punching shear failures that occurred at interior slab-column connections could be post-calculated using analytical methods. The building was evaluated using: 1) a code level strength analysis, 2) a static nonlinear (“pushover”) analysis, and 3) a dynamic nonlinear response analysis using ground motions recorded within 1 km (0.6 mi.) of the building. Based on design material properties and field observations, both the static and dynamic nonlinear analyses were able to successfully post-calculate the observed punching shear failures.

Structurae ne peut pas vous offrir cette publication en texte intégral pour l'instant. Le texte intégral est accessible chez l'éditeur. DOI: 10.1193/1.1585954.