Evaluation and Performance Testing of Eccentric Rolling Isolation System

Auteur(s): ORCID
ORCID
ORCID
ORCID
ORCID
Médium: article de revue
Langue(s): anglais
Publié dans: Structural Control and Health Monitoring, , v. 2024
Page(s): 1-19
DOI: 10.1155/2024/8845965
Abstrait:

Seismic isolation has become a widely accepted method for the protection of structures and nonstructural components. However, this control strategy is unfavorable against near-fault earthquakes, particularly those featuring velocity-pulse effects. Excessive isolation displacements and accelerations can occur during such earthquakes, resulting in amplified responses of the superstructure. To resolve this problem, this study develops a prototype of the eccentric rolling isolation system consisting of one platform eccentrically pin-connected to four circular rollers. The eccentric pin connection yields a nonlinear restoring force of the proposed system and results in displacement-dependent resonances, and the inherent mechanical friction also yields an energy dissipation capability of the system. As the magnitude of ground excitation increases, the prototype system generates a lower resonant frequency away from the dominant frequencies of earthquakes. This behavior is experimentally investigated and verified for mechanical behavior and seismic performance. In the experiment, sinusoidal, far-field, and near-fault ground motions are considered in shaking table testing. Some parameters, such as the eccentricity, roller size, and inertial force, are also experimentally investigated. As found in the experimental result, the feasibility of the prototype system is successfully verified. Meanwhile, the comparable simulation results further validate the mathematical model of the prototype system. Consequently, the eccentric rolling isolation system has demonstrated isolation effectiveness against far-field ground motions and has good potential to perform better than a linear system under near-fault ground motions.

Structurae ne peut pas vous offrir cette publication en texte intégral pour l'instant. Le texte intégral est accessible chez l'éditeur. DOI: 10.1155/2024/8845965.
  • Informations
    sur cette fiche
  • Reference-ID
    10769987
  • Publié(e) le:
    29.04.2024
  • Modifié(e) le:
    29.04.2024
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine