Evaluating the Indoor Air Quality after Renovation at the Greens in Dubai, United Arab Emirates

Auteur(s): ORCID
ORCID
Médium: article de revue
Langue(s): anglais
Publié dans: Buildings, , n. 8, v. 11
Page(s): 353
DOI: 10.3390/buildings11080353
Abstrait:

The Public Health and Safety Department of Dubai Municipality had evaluated the indoor air quality in public buildings in 2013, then established the IAQ (Indoor Air Quality) regulation. Even though IAQ in public building is in control, indoor air pollution in new and renovated housing is still very problematic. The objective of this paper is to measure the indoor air quality of the residential unit in an apartment after renovation to evaluate the actual condition and to analyze the influential factors. As a methodology, field measurements, resident interviews, and observations were conducted for 20 residential units to investigate basic information, renovation contents, ventilation characteristics, and SBS (Sick Building Syndrome) symptoms. The results showed that renovation related to the indoor air quality was the replacement of finishing materials. It was statistically proven that the average CO2 for each house was 683–2309.4 ppm, and 15 houses exceeded the WHO IAQ standards. TVOC had an average concentration of 0–3.0 ppm per house, exceeding the standard in 10 houses. Formaldehyde (CH2O) had an average concentration of 0–1.02 ppm per house, exceeding the WHO IAQ standard (0.1 ppm) in 12 houses. However, even though the indoor air quality was polluted, the residents were hardly aware of it based on subjective response survey. As the amount of renovation increases, the concentration of formaldehyde (CH2O) increases significantly, and excessive renovation should be avoided. This study will serve as a basic dataset to suggest that the new IAQ regulation not be compulsory for residents; rather, they must induce contractors with stipulation to maintain IAQ during and after renovation.

Copyright: © 2021 by the authors; licensee MDPI, Basel, Switzerland.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10625755
  • Publié(e) le:
    26.08.2021
  • Modifié(e) le:
    14.09.2021
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine