Energy Performance of 3D-Printed Concrete Walls: A Numerical Study
Auteur(s): |
Thadshajini Suntharalingam
Irindu Upasiri Perampalam Gatheeshgar Keerthan Poologanathan Brabha Nagaratnam Paulo Santos Heshachanaa Rajanayagam |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Buildings, 22 septembre 2021, n. 10, v. 11 |
Page(s): | 432 |
DOI: | 10.3390/buildings11100432 |
Abstrait: |
Three-dimensional-printed concrete (3DPC), which is also termed as digital fabrication of concrete, offers potential development towards a sustainable built environment. This novel technique clearly reveals its development towards construction application with various global achievements, including structures such as bridges, houses, office buildings, and emergency shelters. However, despite the enormous efforts of academia and industry in the recent past, the application of the 3DPC method is still challenging, as existing knowledge about its performance is limited. The construction industry and building sectors have a significant share of the total energy consumed globally, and building thermal efficiency has become one of the main driving forces within the industry. Hence, it is important to study the thermal energy performance of the structures developed using the innovative 3DPC technique. Thermal characterization of walls is fundamental for the assessment of the energy performance, and thermal insulation plays an important role in performance enhancements. Therefore, in this study, different wall configurations were examined, and the conclusions were drawn based on their relative energy performance. The thermal performance of 32 different 3DPC wall configurations with and without cavity insulation were traced using validated finite element models by measuring the thermal transmittance value (U-value). Our study found that the considered 3DPC cavity walls had a low energy performance, as the U-values did not satisfy the standard regulations. Thus, their performance was improved with cavity insulation. The simulation resulted in a minimum thermal transmittance value of 0.34 W/m²·K. Additionally, a suitable equation was proposed to find the U-values of 100 mm-thick cavity wall panels with different configurations. Furthermore, this study highlights the importance of analytical and experimental solutions as an outline for further research |
Copyright: | © 2021 by the authors; licensee MDPI, Basel, Switzerland. |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original. |
12.83 MB
- Informations
sur cette fiche - Reference-ID
10631239 - Publié(e) le:
01.10.2021 - Modifié(e) le:
05.10.2021