Energy Optimization for Fenestration Design: Evidence-Based Retrofitting Solution for Office Buildings in the UAE

Auteur(s):

ORCID
ORCID
Médium: article de revue
Langue(s): anglais
Publié dans: Buildings, , n. 10, v. 12
Page(s): 1541
DOI: 10.3390/buildings12101541
Abstrait:

With the prevalent use of large glazings, particularly in office buildings, offices receive an abundance of light and are among the largest consumers of electricity. Moreover, in an extreme hot arid climate such as in the UAE, achieving comfortable daylighting levels without increasing solar heat gain is a challenge, in which the window or fenestration design plays an essential role. This research adopts a case study of a higher education (HE) office building on the United Arab Emirates University (UAEU) campus, selected to investigate an evidence-based retrofitting solution for the west façade that can be applied in existing office buildings in the UAE in order to reduce cooling energy load as well as enhance indoor environmental quality. To achieve an evidence-based retrofitting solution, the research design built upon a comprehensive exploratory investigation that included indoor environmental quality physical monitoring and occupant satisfaction surveying. Model simulation was performed by means of DesignBuilder software to perform a single- and multiparameter sensitivity analysis for three key passive window design parameters, i.e., window-to-wall ratio, glazing type, and external shading, aimed towards minimizing annual cooling load and solar heat gain, while maintaining appropriate indoor daylight illuminance levels. The results highlight the importance of the window-to-wall ratio (WWR), as it is the single most significant parameter effecting total energy consumption and daylighting levels. The results recommend 20–30% WWR as the optimum range in the west façade. However, by utilizing high performance glazing types and external shading, equal energy savings can be achieved with a larger WWR. Double Low E tinted glazing and 0.4 projection shading overhang and side fin revealed a noteworthy reduction of energy use intensity of 14%. The study concludes with final retrofitting solutions and design recommendations that aim to contribute validated knowledge towards enhancing window performance in a hot arid climate to guide architects and stakeholders to apply a range of passive parameters towards reducing energy consumption and improving occupant comfort in office buildings.

Copyright: © 2022 by the authors; licensee MDPI, Basel, Switzerland.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10700218
  • Publié(e) le:
    11.12.2022
  • Modifié(e) le:
    15.02.2023
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine