The Effect of Window Placement on Natural Ventilation Capability in a Jakarta High-Rise Building Unit

Auteur(s): ORCID

ORCID


Médium: article de revue
Langue(s): anglais
Publié dans: Buildings, , n. 5, v. 13
Page(s): 1141
DOI: 10.3390/buildings13051141
Abstrait:

The purpose of this study was to investigate the natural ventilation potential in an apartment unit in a high-rise building. A corner unit of a two-bedroom apartment was selected for this study, where single-sided and cross ventilation occurred in the unit. This study employed a CFD simulation to model the indoor airflow of an apartment unit in West Jakarta. The units were modelled and simulated using CFD with a RANS k-ε turbulence model. The results were validated with the readings from the field measurements that had been conducted. Based on CFD results, the window position influences indoor airflow. In the case of cross ventilation, a windward opening is more beneficial, while in single-sided ventilation, a leeward opening creates more indoor airflow. Therefore, it is recommended that the characteristic of window design be considered in the early design stage not only to improve indoor air quality but also to maintain privacy and safety measures.

Copyright: © 2023 by the authors; licensee MDPI, Basel, Switzerland.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10728313
  • Publié(e) le:
    30.05.2023
  • Modifié(e) le:
    01.06.2023
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine