Abstrait: |
This paper presents an evaluation of the bearing capacity of cross-bracing in steel transmission tower structures. Design guidelines (ASCE 10-15, BS EN 50341-1, GB 50017-2017, and DL/T 5486-2020) related to the buckling capacity of the cross-bracing are summarized and compared with the experimental results. The current design provisions obtained the bearing capacity from the equivalent slenderness ratio, and then the stability coefficient and buckling capacity were derived. The calculated bearing capacity based on the design code tends to be overly progressive for smaller slenderness ratios (particularly those below 100), except for EN 50341-1-2012. Conversely, for larger slenderness ratios, ASCE 10-15 and DL/T 5486-2020 Class A design codes lean towards being overly progressive, while GB 50017-2017 and EN 50341-1-2012 codes tend to be more conservative. The design standard appears to exhibit unsafe predictions for Class A and B connections with low slenderness ratios and Class C connections. It needs to be noted that the effects of torsional stiffness and joint connection type are not considered in the current design codes, which are proved to be nonnegligible by the test results. In this paper, the bearing capacity calculation formula is proposed by introducing a modified effective length coefficient (K), and both the torsional stiffness and joint connection type are taken into account. The modified bearing capacity is verified with the test results; the correlation coefficient is 0.997, and the coefficient of variation is 0.04. It can provide a reference for the engineering design of steel lattice transmission tower structures. |
Copyright: | © 2024 by the authors; licensee MDPI, Basel, Switzerland. |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original. |
3.13 MB
- Informations
sur cette fiche - Reference-ID
10787977 - Publié(e) le:
20.06.2024 - Modifié(e) le:
20.06.2024