0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Comprehensive Test and Evaluation Analysis of Permeable Concrete (PC) Clogging by Using Steel Slag

Auteur(s):



ORCID
Médium: article de revue
Langue(s): anglais
Publié dans: Advances in Civil Engineering, , v. 2022
Page(s): 1-17
DOI: 10.1155/2022/2866776
Abstrait:

In recent decade, researchers have more attention to water resource protection and forward the concept of sponge city construction. PC is becoming more and more popular as a rainwater management tool because of fast climate changes worldwide. In this experiment, PC specimens were prepared with steel slag as aggregate, and the targeted porosity of specimens was 15%, 20%, and 25% respectively, and the ratio of water to cement was 0.38, 0.4, and 0.42. The PC specimens under the 200 mm high head are the most severely blocked; 0.283 m/s high-speed horizontal runoff appears after the rapid plugging stage later in the other two types of speed tests. With time, the plugging effect of the test specimen is almost the same; the clogging degree of the PC sample with the porosity of 25% is more obvious than that of other porosity test specimens. The PC with large porosity is more serious to clogging because the higher seepage velocity will enter the internal tunnel with higher penetration force, which increases the possibility of clogging. Tests have shown that, at different rainwater runoff head heights, the PC specimens under the 200 mm high head are the most severely blocked; 0.283 m/s high-speed horizontal runoff appears after the rapid plugging stage later in the other two types of speed tests but over time. With time, the plugging effect of the test specimen was almost the same; the clogging degree of the permeable concrete sample with the porosity of 25% is more obvious than that of other porosity test specimens. While it is noticed that the compressive strength of the PC after clogging has decreased in the freeze-thaw environment, the destruction process is faster than the unblocked test specimen.

Copyright: © 2022 Cao Yang et al. et al.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10660753
  • Publié(e) le:
    28.03.2022
  • Modifié(e) le:
    01.06.2022
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine