A Comparative Study on the Distribution Models of Incident Solar Energy in Buildings with Glazing Facades
Auteur(s): |
Shunyao Lu
Xiaoqing Huang Tao Chen Zhengzhi Wang |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Buildings, 10 octobre 2023, n. 10, v. 13 |
Page(s): | 2659 |
DOI: | 10.3390/buildings13102659 |
Abstrait: |
The accurate distribution of solar energy on indoor walls is the basis of simulating the indoor thermal environment, and its specific distribution changes all the time due to the influence of solar azimuth and altitude angle. By analyzing the assumptions of each model, the existing solar energy distribution models are eight kinds in all and are divided into three categories. The solar radiation models in TRNSYS, EnergyPlus, and Airpak software all use the absorption-weighted area ratio method, which assumes that a single interior surface is a whole, but the detailed assumptions of the models used in the three software are different. In the Radiosity-irradiation method, the indoor surfaces are discretized into small surfaces for calculation. The calculation accuracy of solar radiation distribution indoors can be controlled by the number of discrete small surfaces. The Radiosity-irradiation method is implemented by using Matlab software programming in this paper. Through the numerical calculation and analysis of typical cases, the solar distribution results of the absorption-weighted area ratio method and the Radiosity-irradiation method all show the asymmetry. The asymmetrical ratio of direct solar radiation varies during the time between 7.96–9.89, and the minimum turns up at 11:30 in the summer solstice. The asymmetrical ratio of diffuse solar radiation is 3.23 constantly. The asymmetrical ratio of total solar energy is mainly influenced by the direct and diffuse solar feat gain and its value changes in the range from 3.4 to 4.45 in the summer solstice. Calculation comparison and error analysis on the solar radiation models used in TRNSYS, EnergyPlus, and Airpak software are conducted. There are significant errors in the simulation results of all three software. TRNSYS has the highest error among the three software as its results do not change over time. For EnergyPlus, the distribution ratio of floor 1 is too large. Airpak has the smallest error, but the solar radiation distribution ratios of the indoor surfaces near the south glazing facade are underrated, especially the indoor surfaces that have not been exposed to direct solar radiation. |
Copyright: | © 2023 by the authors; licensee MDPI, Basel, Switzerland. |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original. |
7.82 MB
- Informations
sur cette fiche - Reference-ID
10744572 - Publié(e) le:
28.10.2023 - Modifié(e) le:
07.02.2024