Changes in the Strength of the Polymer Concrete Used in the Electroplating Vats Under Operational Load
Auteur(s): |
Lidia Radna
(University of Zielona Gora, Zielona Góra , Poland)
Volodymyr Sakharov (University of Zielona Gora, Faculty of Building, Architecture and Environmental Engineering, Z. Szafrana st 1, 65-516 Zielona Góra , Poland) |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Civil and Environmental Engineering Reports, décembre 2017, n. 4, v. 27 |
Page(s): | 185-193 |
DOI: | 10.1515/ceer-2017-0060 |
Abstrait: |
Due to the strong and aggressive electrolyte media and thermal load, design of the electroplating vats in the copper industry often relies on the resin concrete. The article presents the results of the strength tests of the polymer concrete based on the "Derakane" resin, used in the construction of electroplating vats. Samples were taken from the real vats - both new and 17-year old. Strength tests included compression and bending tensile strength test. To assess the effect of operational conditions the tests were performed on the same-age vats, some of which were never used while others were subjected to the operational load. During the operation, the vats sustained load of the anode and cathode weights, cyclic electrolyte loading with a temperatures up to 60°C. As a result, it was noted that the operational conditions led to the increased strength of the polymer concrete material. |
- Informations
sur cette fiche - Reference-ID
10705278 - Publié(e) le:
19.02.2023 - Modifié(e) le:
19.02.2023