0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Building Damage Assessment Using Intensity SAR Data with Different Incidence Angles and Longtime Interval

Auteur(s):


Médium: article de revue
Langue(s): anglais
Publié dans: Journal of Disaster Research, , n. 3, v. 14
Page(s): 456-465
DOI: 10.20965/jdr.2019.p0456
Abstrait:

When carrying out change detection for building damage assessment using synthetic aperture radar (SAR) intensity images, it is desirable that the observation conditions of the images are similar and acquisition time is close to the earthquake occurrence time. In this way, the influence of the radar operating system and ground temporal changes can be minimized, facilitating high-accuracy assessment results. However, in practice, especially in poor developing areas, it is difficult to obtain ideal images owing to limited pre-event data archives. In the 2015 Gorkha, Nepal earthquake, the TerraSAR-X satellite captured the influenced Sankhu area before and after the earthquake on May 30, 2010 and May 13, 2015, respectively. The pre-event data was obtained in an ascending path with an incidence angle of 41°, whereas the post-event data was obtained in a descending path with an incidence angle of 33°. To apply the obtained data that had different observation conditions and longtime intervals for building damage assessment, two ways were considered and studied. On one hand, the feasibility of change detection considering these factors was investigated. Pixel statistic characteristics were analyzed in twelve test areas to check the influence of temporal changes, and building footprints were buffered considering two different incidence angles. On the other hand, the reliability of classification based on only post-event data was studied. The results showed good classification performance of some texture parameters, such as the “range value” and “standard deviation,” which are worthy of further study. Moreover, the classification results obtained using the post-event data achieved similar accuracy to that using both the pre- and post-event data, preliminarily indicating the research value of post-event data-based building damage detection as it can solve the pre-event data limitation problem once and for all.

Structurae ne peut pas vous offrir cette publication en texte intégral pour l'instant. Le texte intégral est accessible chez l'éditeur. DOI: 10.20965/jdr.2019.p0456.
  • Informations
    sur cette fiche
  • Reference-ID
    10684917
  • Publié(e) le:
    13.08.2022
  • Modifié(e) le:
    18.09.2022
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine