Bearing Capacity Estimation of Bridge Piles Using the Impulse Transient Response Method
Auteur(s): |
Meng Ma
Jianlei Liu Zaitian Ke Yan Gao |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Shock and Vibration, 2016, v. 2016 |
Page(s): | 1-8 |
DOI: | 10.1155/2016/4187026 |
Abstrait: |
A bearing capacity estimation method for bridge piles was developed. In this method, the pulse echo test was used to select the intact piles; the dynamic stiffness was obtained by the impulse transient response test. A total of 680 bridge piles were tested, and their capacities were estimated. Finally, core drilling analysis was used to check the reliability of this method. The results show that, for intact piles, an obvious positive correlation exits between the dynamic stiffness and bearing capacity of the piles. The core drilling analysis proved that the estimation method was reliable. |
Copyright: | © 2016 Meng Ma, Jianlei Liu, Zaitian Ke, Yan Gao |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original. |
3.39 MB
- Informations
sur cette fiche - Reference-ID
10676327 - Publié(e) le:
28.05.2022 - Modifié(e) le:
01.06.2022