Assessment of cover to reinforcement in slabs using different spacer and tying distances
Auteur(s): |
A. P. Maran
M. F. F. Menna Barreto A. B. Rohden D. C. C. Dal Molin J. R. Masuero |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Revista IBRACON de Estruturas e Materiais, octobre 2015, n. 5, v. 8 |
Page(s): | 625-643 |
DOI: | 10.1590/s1983-41952015000500005 |
Abstrait: |
Given that the durability of structures is directly related to the thickness of the cover to reinforcement, it is essential to ensure minimum cover is achieved when building a structure. However, studies show that this is not always the case. One of the reasons for the this problem is the lack of indication, in structural projects, of the positioning of spacers. This situation is compounded by the lack of standards and regulations on the use of spacers (i.e. minimum quantities and required layout). This study assesses three different spacer distances and two different tying distances in order to examine the influence of these factors in the cover to reinforcement. To achieve so, three slabs were prepared in situ using different arrangements. After demoulding, cover thickness was determined using a digital covermeter. It was observed that the factors investigated have a significant influence in the final cover. |