Application of FCTEM60-1 Instrument in Invert Rebar Testing for Highway Tunnel
Auteur(s): |
Qiuzhuo Liu
Yao Wang |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | IOP Conference Series: Materials Science and Engineering, 1 janvier 2020, n. 1, v. 741 |
Page(s): | 012005 |
DOI: | 10.1088/1757-899x/741/1/012005 |
Abstrait: |
The invert of a highway tunnel is the foundation for the entire tunnel structure. Its quality has a direct influence on the stability of tunnel structure. However, in practice the tunnel invert has various defects for a variety of reasons. FCTEM60-1 instrument is able to rapidly cut off the current using constant voltage clamping technique, thus significantly reducing the shallow dead-zone effect of transient electromagnetic (TEM). In this study the instrument is applied to testing invert rebar execution in a highway tunnel. The study result shows FCTEM60-1 instrument successfully detected the invert rebar, demonstrating its feasibility and reference value to tunnel quality test. |
- Informations
sur cette fiche - Reference-ID
10675381 - Publié(e) le:
12.06.2022 - Modifié(e) le: