An analysis of fracture toughness, at third mode fracture in concretes containing fly-ash additives
Auteur(s): |
Grzegorz Golewski
|
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Budownictwo i Architektura, décembre 2013, n. 3, v. 12 |
Page(s): | 145-152 |
DOI: | 10.35784/bud-arch.2011 |
Abstrait: |
This paper presents the results of fracture toughness tests of concrete with fly ash (FA), specified at the third model fracture. Concrete composites with the additives of 0%, 20% and 30% siliceous FA were analysed. Fracture toughness tests were performed on axial torsion machine MTS 809 Axial/Torsional Test System, using the cylindrical specimens with dimensions of 150/300 mm, with a circumferential notch made in the half-height of cylinders. The studies examined effect of FA additive on the parameter KIIIc. The Analysis of the results revealed that a 20% FA additive causes increase in KIIIc, while a 30% FA additive causes decrease in fracture toughness. |
- Informations
sur cette fiche - Reference-ID
10476065 - Publié(e) le:
25.11.2020 - Modifié(e) le:
25.11.2020