Analysis and Design of Multi-Story Building Rettrofitted with Carbon Fibre Reinforced Polymer
Auteur(s): |
K. Natraj
S. Elavenil S. Ragavendra |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | IOP Conference Series: Earth and Environmental Science, 1 décembre 2022, n. 1, v. 1125 |
Page(s): | 012021 |
DOI: | 10.1088/1755-1315/1125/1/012021 |
Abstrait: |
The paper reports the analytical investigation in Multi-storey building located in seismic zone III. This zone is considered as moderate-damage risk zone as per Indian Codal provision and thirty percent of India falls in this category. To improve the seismic performance, externally bonded FRP strengthening techniques are adopted to deficient beam and columns, in this paper, the analysis of building is carried out with and without lateral resisting system (Shear wall) and retrofitting is done by wrapping the deficient beams and column using Carbon Fiber Reinforced Polymer (CFRP sheet) to evaluate the performance of upgraded structural element. |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution 3.0 (CC-BY 3.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée. |
1.7 MB
- Informations
sur cette fiche - Reference-ID
10780473 - Publié(e) le:
12.05.2024 - Modifié(e) le:
12.05.2024