Absorption Characteristics of Suspended Absorbers
Auteur(s): |
L. Kortchmar
M. A. Nabuco De Araujo S. N. Y. Gerges |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Building Acoustics, décembre 1994, n. 4, v. 1 |
Page(s): | 279-286 |
DOI: | 10.1177/1351010x9400100403 |
Abstrait: |
The question of the arrangement of sound absorbers has been under study for some time. In our approach we conducted a sequence of experiments in a reverberation chamber to determine the optimal sound absorption for different configurations of suspended absorbers using various air spaces and a central dividing panel between them. The results obtained were compared with measurements of the panels, tested against a solid backing as specified in ISO-R-354. It is shown that a porous absorber is more efficient at high frequencies if it is suspended in the sound field rather than against a solid backing. It was also found that the efficiency of an air space between the two porous sheets that compose a suspended absorber is moderately increased when a central divider is used. The statistical precision of the test was also investigated. |
- Informations
sur cette fiche - Reference-ID
10479549 - Publié(e) le:
16.11.2020 - Modifié(e) le:
16.11.2020