End Restraints in Steel Angles in Lattice Towers
Author(s): |
Sriram Kalaga
|
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | The Open Civil Engineering Journal, December 2017, n. 1, v. 11 |
Page(s): | 738-747 |
DOI: | 10.2174/1874149501711010738 |
Abstract: |
Introduction:Test data on single angle compression members with various end connection arrangements is used to develop adjustment factors for effective buckling lengths. A connection length parameter is proposed and evaluated based on test data. Results from a total of 31 equal leg test angles with single-, double- bolts and fixed ends are used. Methods:Slenderness ratios considered ranged from 150 to 312. Angle sizes ranged from 38 x 38 x 3.2 (mm) to 89 x 89 x 6.4 (mm). Estimated connection lengths were about 12.5% of the member length for single-bolt joints; 24.7% for double-bolt joints and 45.6% for fixed joints. Computed effective length factors ranged from 0.544 to 0.875. Results:Results seem to indicate that it is possible to define and calculate connection length of a lattice tower angle member. Suggestions for incorporating connection length issues in routine designs are made. |
Copyright: | © 2017 Sriram Kalaga |
License: | This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met. |
0.73 MB
- About this
data sheet - Reference-ID
10175218 - Published on:
02/08/2019 - Last updated on:
02/06/2021