Abstract:

The demand for cement is increasing every day worldwide. To meet this demand, natural resources are rapidly being depleted. The excessive consumption of natural resources encourages researchers to conduct studies on the use of waste materials instead of cement. Marble waste is one of the major natural wastes abundantly generated worldwide. It has been evaluated that there is a gap in the literature regarding a study comparing the effects of different cooling regimes on cementitious composites with a marble powder (MP) replacement that has been exposed to high temperatures. In this study, waste marble powder (MP) was used as a replacement for cement at percentages of 5%, 10%, 15%, 20%, and 25% by mass. The water-to-binder ratio was kept constant at 0.5 for all mixture groups. Subsequently, the prepared cementitious composites were exposed to high temperatures (300 °C, 600 °C, and 800 °C) and subjected to air- and water-cooling regimes. Within the scope of this study, unit weight (Uw), ultrasonic pulse velocity (UPV), flexural strength (ffs), compressive strength (fcs), and mass loss tests were conducted. Additionally, a microstructure analysis was carried out using scanning electron microscopy (SEM) to examine the effect of MP replacement and the cooling regime. When examining the results of the samples tested in the laboratory, it was observed that the mortar with 5% MP replacement exhibited better mechanical properties compared with the others. In general, it can be said that the mechanical properties of samples cooled in air after exposure to high temperatures were better than those of samples cooled in water. As a result of this study, it was determined that MP replacement could positively contribute to the resistance of cementitious composites to high temperatures. Additionally, the use of a significant amount of waste MP can lead to savings in cement usage and significant reductions in CO2 emissions.

Copyright: © 2023 by the authors; licensee MDPI, Basel, Switzerland.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10744558
  • Published on:
    28/10/2023
  • Last updated on:
    07/02/2024
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine