Experimental study and finite element analysis on seismic behavior of flat vertical-diaphragm stiffened concrete-filled SHS column joints

 Experimental study and finite element analysis on seismic behavior of flat vertical-diaphragm stiffened concrete-filled SHS column joints
Autor(en): , , , ,
Beitrag für IABSE Symposium: Construction’s Role for a World in Emergency, Manchester, United Kingdom, 10-14 April 2024, veröffentlicht in , S. 871-878
DOI: 10.2749/manchester.2024.0871
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.22 MB

There are great advantages in adopting steel structure for tall residential buildings. In order to study the mechanical properties of the flat vertical-diaphragm stiffened concrete-filled SHS colum...
Weiterlesen

Bibliografische Angaben

Autor(en): (Tongji Architectural Design (Group) Co., Ltd., Shanghai, China)
(Tongji Architectural Design (Group) Co., Ltd., Shanghai, China)
(Tongji University, Shanghai, China)
(Tongji University, Shanghai, China)
(China Overseas Property Group Co., Ltd., Shenzhen, China)
(China Overseas Property Group Co., Ltd., Shenzhen, China)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Symposium: Construction’s Role for a World in Emergency, Manchester, United Kingdom, 10-14 April 2024
Veröffentlicht in:
Seite(n): 871-878 Anzahl der Seiten (im PDF): 8
Seite(n): 871-878
Anzahl der Seiten (im PDF): 8
DOI: 10.2749/manchester.2024.0871
Abstrakt:

There are great advantages in adopting steel structure for tall residential buildings. In order to study the mechanical properties of the flat vertical-diaphragm stiffened concrete-filled SHS column joints, such as stiffness, bearing capacity, failure mode, and deformation capacity, full-scale tests and finite element analysis are conducted based on the actual case in China. Results of cyclic tests are listed in this paper. Proper design suggestions and a scientific foundation are provided to the application of this kind of joints accordingly. The test results show that the failure mode of specimen FCFST-S- H is ductile failure due to connection loss and the failure mode of specimen FCFST-C-H is observed as connection failure. In both sets of cyclic loading tests, the joint has good energy dissipation capacity. The finite element analysis results are consistent with the test results.

Stichwörter:
Finite-Elemente-Analyse