Evaluation of Concrete Properties for High Strength Steel Applications

 Evaluation of Concrete Properties for High Strength Steel Applications
Autor(en): , , , ,
Beitrag für IABSE Conference: Assessment, Upgrading and Refurbishment of Infrastructures, Rotterdam, The Netherlands, 6-8 May 2013, veröffentlicht in , S. 360-361
DOI: 10.2749/222137813806501614
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.17 MB

Utilizing High-Strength Steel Rebars (HSR) as reinforcement in concrete structures has widely increased recently. However, the American Concrete Institute (ACI) in the ACI-318-11 building code requ...
Weiterlesen

Bibliografische Angaben

Autor(en):






Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Conference: Assessment, Upgrading and Refurbishment of Infrastructures, Rotterdam, The Netherlands, 6-8 May 2013
Veröffentlicht in:
Seite(n): 360-361 Anzahl der Seiten (im PDF): 8
Seite(n): 360-361
Anzahl der Seiten (im PDF): 8
Jahr: 2013
DOI: 10.2749/222137813806501614
Abstrakt:

Utilizing High-Strength Steel Rebars (HSR) as reinforcement in concrete structures has widely increased recently. However, the American Concrete Institute (ACI) in the ACI-318-11 building code requirements for structural concrete specifies the yield strength to be the stress corresponding to a strain of 0.35%, if rebars with yield stresses higher than 420MPa to be used. This limit is to ensure ductile behavior and avoid concrete crushing as a controlling failure mode. Due to the brittle nature and very high strength of most commercially available high-strength steel rebars there is an inherent difficulty in achieving the steel’s strength through yielding without the concrete crushing and causing a catastrophic brittle failure. The possible problems that could arise from the use of HSR with its limited ductility are: less frequent yet deeper cracks in the concrete matrix, issues with the bond between steel and concrete, and pre-mature or undetected failure in the tensile planes within the member. In addition, a recent study concluded that for serviceability and cracking control, stresses in steel should be limited to 50% of the yield strength to have similar performance of Grade 60 steel. In this paper, extensive evaluation of concrete mixes with different compressive strengths with and without steel fiber will be presented as solutions to such challenges. Also to emphasis the expected benefits of adding steel fiber to improve post cracking behavior, test results will be discussed and presented.

Stichwörter:
Versagen höherfester Stahl Streckgrenze duktil