0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Desirable Geometrical Configurations of The Web/Flange Splices for Enhancing the Frictional Slip Resistance of an I-Girder

 Desirable Geometrical Configurations of The Web/Flange Splices for Enhancing the Frictional Slip Resistance of an I-Girder
Autor(en): ,
Beitrag für IABSE Congress: Bridges and Structures: Connection, Integration and Harmonisation, Nanjing, People's Republic of China, 21-23 September 2022, veröffentlicht in , S. 592-599
DOI: 10.2749/nanjing.2022.0592
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.2 MB

The present study focuses on the major slip behavior of high-strength frictional bolted connections in an I-girder. Bolted girder connections resist the applied bending moment through the cooperati...
Weiterlesen

Bibliografische Angaben

Autor(en): (Osaka City University, Osaka, Japan)
(Osaka City University, Osaka, Japan)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Congress: Bridges and Structures: Connection, Integration and Harmonisation, Nanjing, People's Republic of China, 21-23 September 2022
Veröffentlicht in:
Seite(n): 592-599 Anzahl der Seiten (im PDF): 8
Seite(n): 592-599
Anzahl der Seiten (im PDF): 8
DOI: 10.2749/nanjing.2022.0592
Abstrakt:

The present study focuses on the major slip behavior of high-strength frictional bolted connections in an I-girder. Bolted girder connections resist the applied bending moment through the cooperation of flange and web resistances. Flange and web splices are individually designed following practical design codes, such as Eurocode 3 and the Japanese Specifications for Highway Bridges. In the present study, FEA of various cross-sectional dimensions of the web splice in girder bolted connections, having various bolt arrangements of the web splice, and various number of bolts in the flange and web splices have been conducted to quantitatively evaluate the cooperative slip behavior of the girder connections. It has been found that the frictional force of the web splice was small compared to the design resistance. Moreover, as the bolt spacing of the web splice increased and the number of bolt rows of the web splice decreased, the ratio of the frictional force to the design slip resistance increased.

Copyright: © 2022 International Association for Bridge and Structural Engineering (IABSE)
Lizenz:

Die Urheberrechte (Copyright) für dieses Werk sind rechtlich geschützt. Es darf nicht ohne die Zustimmung des Autors/der Autorin oder Rechteinhabers/-in weiter benutzt werden.