Use of Integrated Viscous Dampers to Control Wind Induced Vibrations in Tall Buildings

 Use of Integrated Viscous Dampers to Control Wind Induced Vibrations in Tall Buildings
Autor(en): , ,
Beitrag für IABSE Congress: The Evolving Metropolis, New York, NY, USA, 4-6 September 2019, veröffentlicht in , S. 362-368
DOI: 10.2749/newyork.2019.0362
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.65 MB

The tall building world is seeing a trend pushing building heights and slenderness ratios to levels previously unseen. The design of these buildings for both strength and serviceability is typicall...
Weiterlesen

Bibliografische Angaben

Autor(en): (Arup)
(Arup)
(Arup)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Congress: The Evolving Metropolis, New York, NY, USA, 4-6 September 2019
Veröffentlicht in:
Seite(n): 362-368 Anzahl der Seiten (im PDF): 7
Seite(n): 362-368
Anzahl der Seiten (im PDF): 7
DOI: 10.2749/newyork.2019.0362
Abstrakt:

The tall building world is seeing a trend pushing building heights and slenderness ratios to levels previously unseen. The design of these buildings for both strength and serviceability is typically governed by the dynamic response of the building to wind. Comfort of building occupants during relatively low return period wind events is a key challenge, and engineers are increasingly turning to damping technologies to limit building accelerations rather than adding stiffness or mass. Large tuned mass dampers (TMDs) are a commonly used solution.

This paper suggests that integrating viscous dampers within a tall building’s structure can deliver a cost- effective alternative to TMDs, delivering high performing buildings with additional benefits in terms of robustness and space efficiency.

Two case studies are presented. Firstly, measured data from a tower in New York with viscous dampers integrated into the structure is provided, comparing design stage predictions to real-life performance. Furthermore, a case study for a super-slender tower is described, demonstrating the potential for enhanced performance and significant cost and space savings using integrated damping.

Stichwörter:
Beschleunigungen

Bauwerke und Projekte