Load-carrying capacity of two 110 year old steel portal frame bridges

 Load-carrying capacity of two 110 year old steel portal frame bridges
Autor(en):
Beitrag für IABSE Congress: Challenges in Design and Construction of an Innovative and Sustainable Built Environment, Stockholm, Sweden, 21-23 September 2016, veröffentlicht in , S. 621-628
DOI: 10.2749/stockholm.2016.0600
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.19 MB

The load-carrying capacity of two old steel portal frame bridges, built in 1907 and 1912 has been determined, using FE-models and taking into account the damage due to corrosion, found during inspe...
Weiterlesen

Bibliografische Angaben

Autor(en): (Civil Engineering Department, Ghent University, Belgium)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Congress: Challenges in Design and Construction of an Innovative and Sustainable Built Environment, Stockholm, Sweden, 21-23 September 2016
Veröffentlicht in:
Seite(n): 621-628 Anzahl der Seiten (im PDF): 8
Seite(n): 621-628
Anzahl der Seiten (im PDF): 8
Jahr: 2016
DOI: 10.2749/stockholm.2016.0600
Abstrakt:

The load-carrying capacity of two old steel portal frame bridges, built in 1907 and 1912 has been determined, using FE-models and taking into account the damage due to corrosion, found during inspection. For this, adequate real traffic models have been used. The capacity of both bridges proved to be insufficient, mainly due to corrosion of the outside portals. The frame cross-sections are asymmetrical, since reduction of the area is considered for tension and not for compressed parts. Two alternatives are considered for refurbishment. Replacing corroded plates and profiles on site being impossible, the alternative to reduce dead weight seems more feasible.

Stichwörter:
Nietkonstruktion

Bauwerke und Projekte

Bauwerkstypen