0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

In-plane Shear Test of Floor Structure Adapting for the CSTS Using a Cross Laminated Timber

 In-plane Shear Test of Floor Structure Adapting for the CSTS Using a Cross Laminated Timber
Autor(en): , , ,
Beitrag für IABSE Congress: Challenges in Design and Construction of an Innovative and Sustainable Built Environment, Stockholm, Sweden, 21-23 September 2016, veröffentlicht in , S. 1379-1384
DOI: 10.2749/stockholm.2016.1374
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.19 MB

In light of the global environment issues, the authors proposed a building system comprising steel and timber structure (Hereafter referred to as CSTS) and its design method, which consist of rolle...
Weiterlesen

Bibliografische Angaben

Autor(en): (Nice Corporation Ltd., M. Eng., Japan)
(Nice Corporation Ltd., M. Eng., Japan)
(Nice Corporation Ltd., M. Eng., Japan)
(Kanagawa University, Yokohama, Japan)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Congress: Challenges in Design and Construction of an Innovative and Sustainable Built Environment, Stockholm, Sweden, 21-23 September 2016
Veröffentlicht in:
Seite(n): 1379-1384 Anzahl der Seiten (im PDF): 6
Seite(n): 1379-1384
Anzahl der Seiten (im PDF): 6
Jahr: 2016
DOI: 10.2749/stockholm.2016.1374
Abstrakt:

In light of the global environment issues, the authors proposed a building system comprising steel and timber structure (Hereafter referred to as CSTS) and its design method, which consist of rolled section steel and timber. The CSTS is assumed to be mid-rise story building steel structures. This design method use concept of a damage controlled structure with a buckling-restrained brace as a seismic response control member and its analytical model is established based on the available experimental studies. The CSTS is aiming to expand to be used from main structure to floor structure in the building of the non-residential sector and assumed to use materials such as a cross laminated timber for floor structure. This cross laminated timber has a high stiffness and strength because it is joined by multi-layer panels.

In this study, we propose floor structure adapting for the CSTS using cross laminated timber. In- plane shear test of the joint which are consisted of unheaded stud-shear connectors for joint of the CSTS beam and floor structure is conducted. Structural performances of joint of the CSTS beam and floor structure are evaluated. The findings obtained from tests indicate that joint of the CSTS beam and floor structure has a high stiffness and strength.

Stichwörter:
Stahl Verbundkonstruktion