0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Failure Behaviour of Bonding Interface for the Continuous Slab Track Structure Under Temperature Load

 Failure Behaviour of Bonding Interface for the Continuous Slab Track Structure Under Temperature Load
Autor(en): ,
Beitrag für IABSE Conference: Bridges and Structures Sustainability - Seeking Intelligent Solutions, Guangzhou, China, 8-11 May 2016, veröffentlicht in , S. 106-113
DOI: 10.2749/222137816819258302
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.29 MB

Continuous slab track which consist of prefabricate track slab, cement asphalt mortar layer and base plate has been widely used in the ballastless track system of the high-speed railway in China. B...
Weiterlesen

Bibliografische Angaben

Autor(en):

Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Conference: Bridges and Structures Sustainability - Seeking Intelligent Solutions, Guangzhou, China, 8-11 May 2016
Veröffentlicht in:
Seite(n): 106-113 Anzahl der Seiten (im PDF): 8
Seite(n): 106-113
Anzahl der Seiten (im PDF): 8
Jahr: 2016
DOI: 10.2749/222137816819258302
Abstrakt:

Continuous slab track which consist of prefabricate track slab, cement asphalt mortar layer and base plate has been widely used in the ballastless track system of the high-speed railway in China. Both the prefabricate track slab and the base plate are continuously longitudinally so that the breaking joint was avoided at the seams of beam end. Past research mostly focus on the base plate as it is the main bearing member and ignoring the interfacial working performance. However, the cracks which happened in the interface between the prefabricate track slab and cement asphalt mortar were found in the process of the operation. Once the interface cracked, the track slab lost the restraints and would bend up or sliding in longitudinal under the temperature load.

This paper mainly introduced the common failure modes of the continuous slab track and presented the theoretical of the interfacial stresses under elastic condition. Based on experimental test, the deformation, the interface ultimate bearing capacity and the failure mechanisms of the ballastless track system affected by the temperature load were discussed. According to the CCD camera test results, the bond strength difference of the top and low interface of the mortar layer were discussed. In addition, the interfacial stresses were studied by using the nonlinear finite element model.