The Behavior of Rion - Antirion Bridge Seismic Protection System During the Earthquake of "Achaia-Ilia" on June 8, 2008

The Behavior of Rion - Antirion Bridge Seismic Protection System During the Earthquake of "Achaia-Ilia" on June 8, 2008
Autor(en): , ,
Beitrag für IABSE Symposium: Large Structures and Infrastructures for Environmentally Constrained and Urbanised Areas, Venice, Italy, 22-24 September 2010, veröffentlicht in , S. 306-307
DOI: 10.2749/222137810796024619
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.03 MB

On June 08, 2008 at 15:25 a strong earthquake with moment magnitude Mw=6,5, named “Achaia- Ilia” occurred in Greece. The focal depth was estimated to be around 30km and the epicentre was located at...
Weiterlesen

Bibliografische Angaben

Autor(en):


Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Symposium: Large Structures and Infrastructures for Environmentally Constrained and Urbanised Areas, Venice, Italy, 22-24 September 2010
Veröffentlicht in:
Seite(n): 306-307 Anzahl der Seiten (im PDF): 8
Seite(n): 306-307
Anzahl der Seiten (im PDF): 8
Jahr: 2010
DOI: 10.2749/222137810796024619
Abstrakt:

On June 08, 2008 at 15:25 a strong earthquake with moment magnitude Mw=6,5, named “Achaia- Ilia” occurred in Greece. The focal depth was estimated to be around 30km and the epicentre was located at a distance 36 km SW from the Rion-Antirion Bridge.

The Rion-Antirion Bridge, a five-span cable-stay bridge (286m + 560m + 560m + 560m + 286m), has been designed to withstand earthquakes with P.G.A. of 0,48g and tectonic movements up to 2m between consecutive pylons. In order to satisfy the above requirements the deck superstructure was made continuous for the full length of 2252m and fully suspended from the four pylons.

An innovative energy dissipation system, designed by Vinci and developed by FIP Industriale, connects the deck to the pylons and limits the lateral movement of the deck during an earthquake, while dissipating the seismic energy with huge – never built before - viscous dampers. The bridge is also equipped with a complete monitoring system capable of collecting high frequency data at critical parts of the structure during a seismic or wind dynamic event.

The paper presents evidences of the good performance of the dissipation system during the above mentioned earthquake. From the analysis of the monitoring data collected during the event and the thorough inspections performed after, it was confirmed that the behaviour of the bridge was in accordance with the analytical predictions and well within the serviceability limit states.

Stichwörter:
Schrägseilbrücke

Bauwerke und Projekte