Evaluación de la energía disipada en los apoyos, en el ensayo RILEM de medida de la energía de fractura en el hormigón
Autor(en): |
G. V. Guinea
J. Planas M. Elices |
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch, Spanisch |
Veröffentlicht in: | Hormigón y acero, 3. Quartal 1990, n. 176, v. 41 |
Seite(n): | 103-110 |
Abstrakt: |
RILEM test evaluation of concrete ffracture energy. A study of energy dissipation at the supportsActual experimental arrangements may differ appreciably from the ideal design and these are always a limit to the accuracy of the measurements. Here we consider a main source of experimental error; the energy dissipation at the supports, when using the RILEM test for GF measurement. Friction at the supports is an important source of experimental error. Friction coefficients must be kept below 0.02-0.04 for friction to be negligible within 1 percent accuracy. Good rolling supports are needed to achieve these low functional levels. |