Wind-induced Modal Identification of the Bosphorus Bridge using SHM-Structural Health Monitoring Data

 Wind-induced Modal Identification of the Bosphorus Bridge using SHM-Structural Health Monitoring Data
Autor(en): , ,
Beitrag für IABSE Symposium: Engineering the Future, Vancouver, Canada, 21-23 September 2017, veröffentlicht in , S. 159-166
DOI: 10.2749/vancouver.2017.0159
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.22 MB

Wind vibration characteristics of the Bosphorus Bridge is investigated using SHM data. The Bosphorus Bridge with the main span length of 1074 m and two side spans was instrumented due to the critic...
Weiterlesen

Bibliografische Angaben

Autor(en):


Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Symposium: Engineering the Future, Vancouver, Canada, 21-23 September 2017
Veröffentlicht in:
Seite(n): 159-166 Anzahl der Seiten (im PDF): 8
Seite(n): 159-166
Anzahl der Seiten (im PDF): 8
Jahr: 2017
DOI: 10.2749/vancouver.2017.0159
Abstrakt:

Wind vibration characteristics of the Bosphorus Bridge is investigated using SHM data. The Bosphorus Bridge with the main span length of 1074 m and two side spans was instrumented due to the critical event in 2004 leading to damage to a hanger element. Totally 168 sensors were mounted on the bridge for its monitoring system. Due to the geographic location of Istanbul, strong winds are not expected for the bridges. However, the Bosphorus Bridge experienced a critical wind load in 2012, resulting in large displacement in transverse direction. During the event, wind speed reached to approximately 100 km/h from the average speed of 20 km/h within a short duration of 10 min. Therefore, it is significant to determine the influence of this event on the response of the bridge. For this objective, the data pre-processing including windowing and overlapping is first done to get rid of distorting effects of noise content on the data. The refined data, afterwards, is considered for structural identification of the bridge. Implementing the fundamental identification method of FFT, mode shapes and corresponding frequencies of the bridge are obtained. The comparison of the results during strong wind with those from after the extreme event showed that strong wind led to higher modal period values in the transverse and vertical modes, which can be attributed to a more flexible bridge behavior under this event. Along with the low modal frequencies obtained during the strong wind, the bridge is estimated to have high damping capacity under extreme loading. In addition, the modal frequencies obtained after the strong wind proves no damage to the bridge since these values are equal to natural vibration values of the bridge under normal operation conditions.

Stichwörter:
Hängebrücke

Bauwerke und Projekte