0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Stress-strain Model Adapted to Bolted Connection in Ultimate Behaviour Considering Energy Absorption

 Stress-strain Model Adapted to Bolted Connection in Ultimate Behaviour Considering Energy Absorption
Autor(en): ,
Beitrag für IABSE Congress: Bridges and Structures: Connection, Integration and Harmonisation, Nanjing, People's Republic of China, 21-23 September 2022, veröffentlicht in , S. 1465-1472
DOI: 10.2749/nanjing.2022.1465
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.15 MB

Bolted connection is one of the well-used techniques to connect structural members of steel bridges. Not only load capacity but also energy absorption are important characteristics of the structure...
Weiterlesen

Bibliografische Angaben

Autor(en): (Kyushu Institute of Technology, Kitakyushu, Japan)
(Kyushu Institute of Technology, Kitakyushu, Japan)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Congress: Bridges and Structures: Connection, Integration and Harmonisation, Nanjing, People's Republic of China, 21-23 September 2022
Veröffentlicht in:
Seite(n): 1465-1472 Anzahl der Seiten (im PDF): 8
Seite(n): 1465-1472
Anzahl der Seiten (im PDF): 8
DOI: 10.2749/nanjing.2022.1465
Abstrakt:

Bolted connection is one of the well-used techniques to connect structural members of steel bridges. Not only load capacity but also energy absorption are important characteristics of the structure to resist seismic action. In a finite element analysis, a true stress-true strain material model is needed to obtain an accurate evaluation in case the structure is exposed to excessive forces and deformed largely, although the true stress-true strain model is almost the same as to nominal stress-strain model in the small strain part. This study proposes a simple true stress-true strain model. And, the validity of the model was confirmed by the compare the finite element analysis and steel material tensile test or tensile experiment of bolted connection. Some true stress-true strain models were investigated and discussed from the viewpoint of load capacity and energy absorption.