Slipping Behavior and Relaxation Characteristics of Thin-Walled GFRP High-Strength Bolted Friction Joints for Sound Barriers on Bridge Viaducts

 Slipping Behavior and Relaxation Characteristics of Thin-Walled GFRP High-Strength Bolted Friction Joints for Sound Barriers on Bridge Viaducts
Autor(en): , , , ,
Beitrag für IABSE Congress: Bridges and Structures: Connection, Integration and Harmonisation, Nanjing, People's Republic of China, 21-23 September 2022, veröffentlicht in , S. 490-497
DOI: 10.2749/nanjing.2022.0490
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.25 MB

This study aimed to clarify the performance of high-strength bolted joints for thin-walled glass-fiber- reinforced polymer (GFRP) members by conducting slip tests and long-term relaxation tests. Th...
Weiterlesen

Bibliografische Angaben

Autor(en): (Osaka Metropolitan University, Osaka, Japan)
(Osaka Metropolitan University, Osaka, Japan)
(Osaka Metropolitan University, Osaka, Japan)
(Miyaji Engineering Co. Ltd., Tokyo, Japan)
(Miyaji Engineering Co. Ltd., Tokyo, Japan)
(Miyaji Engineering Co. Ltd., Tokyo, Japan)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Congress: Bridges and Structures: Connection, Integration and Harmonisation, Nanjing, People's Republic of China, 21-23 September 2022
Veröffentlicht in:
Seite(n): 490-497 Anzahl der Seiten (im PDF): 8
Seite(n): 490-497
Anzahl der Seiten (im PDF): 8
DOI: 10.2749/nanjing.2022.0490
Abstrakt:

This study aimed to clarify the performance of high-strength bolted joints for thin-walled glass-fiber- reinforced polymer (GFRP) members by conducting slip tests and long-term relaxation tests. The parameters of the slip test were the FRP surface treatment, bolt axial force, and bolt hole diameter. Relaxation characteristics might also be affected by variations in fiber content based on differences in production lots. Hence, samples from different production lots were taken. However, in these tests, the influence of all parameters was relatively minimal. One year after tightening, the axial force reduction gradually subsided and tended toward convergence. However, because it is difficult to determine convergence based on temperature changes, long-term measurements will continue. In the slip tests, the highest slip coefficient was obtained when the GFRP was coated with fluoroplastic and the connecting plates were treated with phosphate. This study proposes a design slip coefficient for GFRP high-strength bolted friction joints.

Stichwörter:
GFK
Copyright: © 2022 International Association for Bridge and Structural Engineering (IABSE)
Lizenz:

Die Urheberrechte (Copyright) für dieses Werk sind rechtlich geschützt. Es darf nicht ohne die Zustimmung des Autors/der Autorin oder Rechteinhabers/-in weiter benutzt werden.