With the increase of height and flexibility of modern super tall buildings, the structural natural vibration period become longer and longer. The long period components become the dominant factor ...
Weiterlesen

Bibliografische Angaben

Autor(en):

Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Symposium: Engineering for Progress, Nature and People, Madrid, Spain, 3-5 September 2014
Veröffentlicht in:
Seite(n): 483-490 Anzahl der Seiten (im PDF): 8
Seite(n): 483-490
Anzahl der Seiten (im PDF): 8
Jahr: 2014
DOI: 10.2749/222137814814028061
Abstrakt:

With the increase of height and flexibility of modern super tall buildings, the structural natural vibration period become longer and longer. The long period components become the dominant factor in the structural design of super tall buildings. Due to lack of sufficient ground motion records with rich long period components, current researches on long period components were not fully conducted. To avoid serious structural damages caused by excessive long period responses, the natural vibration period of super tall buildings is commonly requested to be below certain limit in Asian super tall building development practices. The key factors which may cause significant differences on the natural vibration period could be easily found. A super tall building which is above 500 meters was taken as an example to show the sensitivity analysis results of outrigger trusses under natural vibration period constraints. The impacts of the parameters of both diagonal and chord members of the outrigger systems on the natural vibration period were thoroughly investigated. Using the weight of structural members as optimization objective, a period sensitivity index was defined. Through the sensitivity analysis, one may obtain the period sensitivity indices and the optimal outrigger scheme can then be derived for the super tall building structures.

Stichwörter:
Sensitivitätsanalyse