Seismic Performance of Cross Laminated Timber (CLT) Platform Building by Incremental Dynamic Analysis

 Seismic Performance of Cross Laminated Timber (CLT) Platform Building by Incremental Dynamic Analysis
Autor(en): , ORCID, ,
Beitrag für IABSE Symposium: Engineering the Future, Vancouver, Canada, 21-23 September 2017, veröffentlicht in , S. 430-436
DOI: 10.2749/vancouver.2017.0430
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.22 MB

The present study performed Incremental Dynamic Analysis on a case study Cross-laminated timber (CLT) platform building. The building was designed for the seismic modification factors of Rd=2.0 and...
Weiterlesen

Bibliografische Angaben

Autor(en): (PhD Candidate, The University of British Columbia, Canada)
ORCID (University of Northern British Columbia, Canada)
(Associate Professor, The University of British Columbia, Canada)
(Principal Scientist, FPInnovations, Advanced Building Systems, Canada)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Symposium: Engineering the Future, Vancouver, Canada, 21-23 September 2017
Veröffentlicht in:
Seite(n): 430-436 Anzahl der Seiten (im PDF): 7
Seite(n): 430-436
Anzahl der Seiten (im PDF): 7
Jahr: 2017
DOI: 10.2749/vancouver.2017.0430
Abstrakt:

The present study performed Incremental Dynamic Analysis on a case study Cross-laminated timber (CLT) platform building. The building was designed for the seismic modification factors of Rd=2.0 and Ro=1.5 for the soil Class C in Vancouver, BC, Canada. A 2D non-linear finite element model was developed in OpenSees. CLT panels were modelled as orthotropic elastic shell elements and the connections were modelled as non-linear springs that account for both uplift and shear deformation. The connections and wall parameters for hysteresis models were calibrated from test results. The seismic performance of the building was evaluated using the 22 bi-axial ground motions. The seismic demand was recorded in terms of inter-storey drift ratio. The results indicated that the case study CLT platform building has a sufficient factor of safety against collapse (Collapse Margin Ratio of 3.1) under a Maximum Credible Earthquake.

Stichwörter:
Erdbebenbelastung Brettsperrholz finites Element