0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

A Novel Design Concept for Connections in Glass: Structural Integrity of Glass Reinforced with Externally–Bonded GFRP Laminates

A Novel Design Concept for Connections in Glass: Structural Integrity of Glass Reinforced with Externally–Bonded GFRP Laminates
Autor(en): (Faculty of Engineering and the Environment, University of Southampton, SO17 1BJ, UK)
(Faculty of Engineering and the Environment, University of Southampton, SO17 1BJ, UK)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Conference: Creativity and Collaboration – Instilling Imagination and Innovation in Structural Design, Bath, United Kingdom, 19-20 April 2017
Veröffentlicht in:
Seite(n): 45-46
Jahr: 2017
DOI: 10.2749/222137817821233152
Abstrakt:

The paper reports experimental results of the load response and failure behaviour of open-hole annealed glass tensile test specimens reinforced with adhesively-bonded GFRP laminates. The results show that the bonded GFRP has potential to strengthen stress concentration features in glass by either arresting the cracks developed in the critical zone or eliminating the failure from the vicinity of the critical area. It is anticipated that the findings of this research could be effectively used to develop reinforcement strategies for critical joints in glass structures.

Stichwörter:
Fuge Bewehrung Verstärkung Glas GFK