Local Bucklingand Inelastic behaviour of Flexural Members Fabricated from 800MPa Tensile-Strength Steel

 Local Bucklingand Inelastic behaviour of Flexural Members Fabricated from 800MPa Tensile-Strength Steel
Autor(en): ,
Beitrag für 18th IABSE Congress: Innovative Infrastructures – Towards Human Urbanism, Seoul, Korea, 19-21 September 2012, veröffentlicht in , S. 2142-2149
DOI: 10.2749/222137912805112815
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.14 MB

Flexural tests on full-scale I-shaped beams, built up from high-strength steels (HSB800 and HSA800) with a nominal tensile strength of 800 MPa, was carried out to study the effect of flange slender...
Weiterlesen

Bibliografische Angaben

Autor(en):

Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: 18th IABSE Congress: Innovative Infrastructures – Towards Human Urbanism, Seoul, Korea, 19-21 September 2012
Veröffentlicht in:
Seite(n): 2142-2149 Anzahl der Seiten (im PDF): 8
Seite(n): 2142-2149
Anzahl der Seiten (im PDF): 8
DOI: 10.2749/222137912805112815
Abstrakt:

Flexural tests on full-scale I-shaped beams, built up from high-strength steels (HSB800 and HSA800) with a nominal tensile strength of 800 MPa, was carried out to study the effect of flange slenderness on flexural strength and rotation capacity. The primary objective was to investigate the appropriateness of extrapolating current stability criteria (originally developed for ordinary steel) to high-strength steel. The performance of high-strength steel specimens was very satisfactory from the strength, but not from the rotation capacity, perspective. The inferior rotation capacity of high- strength steel beams was shown to be directly attributable to the absence of a distinct yield plateau and the high yield ratio of the material. When a higher rotation capacity is required as in plastic design, the testing clearly showed that high-strength steel beams were vulnerable to brittle fracture when full-height transverse stiffeners were welded to the tension flange in the plastic hinge region. Residual stress measurements reconfirmed that the magnitude of the residual stress is almost independent of the yield stress of the base metal.

Stichwörter:
höherfester Stahl örtliches Beulen