Influence of the Speed of Loading and Discharging of the Test Machine in Determining the Compressive Strength of Concrete
|
Bibliografische Angaben
Autor(en): |
Suélio da Silva Araújo
(Teacher Civil Engineer of the University Center UNIEURO - Brasília - Federal District and Teacher Civil Engineer of the Paulista University – Campus Brasília - Federal District. )
Gilson Natal Guimarães (PhD., University of Texas at Austin, USA (1988). Full Professor at the Federal University of Goiás, Brazil.) André Luiz Bortolacci Geyer (Doctorate in Civil Engineering from the Federal University of Rio Grande do Sul, Brazil (2001). Associate Professor II at the Federal University of Goiás.) |
||||
---|---|---|---|---|---|
Medium: | Tagungsbeitrag | ||||
Sprache(n): | Englisch | ||||
Tagung: | IABSE Congress: Challenges in Design and Construction of an Innovative and Sustainable Built Environment, Stockholm, Sweden, 21-23 September 2016 | ||||
Veröffentlicht in: | IABSE Congress Stockholm, 2016 | ||||
|
|||||
Seite(n): | 2202-2213 | ||||
Anzahl der Seiten (im PDF): | 12 | ||||
Jahr: | 2016 | ||||
DOI: | 10.2749/stockholm.2016.2201 | ||||
Abstrakt: |
This paper presents a comparative analysis of the results obtained for the test of compressive strength, through a program of interlaboratory tests on hardened concrete, the Company developed Carlos Campos Consultoria e Construções Ltda., in the School of Civil Engineering Federal University of Goiás and in the Department of Technical Support and Control of Furnas Centrais Elétricas S.A., located in Goiânia-Goiás, to identify and evaluate the influence of some factors involved in test compressive strength. For this, we sought to verify the result of compressive strength, the influence of the type of processor (A and B) and upload speed (0.3 and 0.6 MPa/s) body-of-proof cylindrical size 150 mm x 300 mm in the concrete class C30. It was concluded that the type of laboratory significantly affect the results of compressive strength. Furthermore, it is noteworthy that the body-of-evidence dimension 150 mm x 300 mm concrete class C30, tested with a loading speed of the testing machine of 0.3 MPa/s presented the results to the larger dispersions. |
||||
Stichwörter: |
Beton Druckfestigkeit
|