Implementation of a Passive Control System in a Lively Footbridge
|
Bibliografische Angaben
Autor(en): |
Elsa Caetano
Ávaro Cunha |
||||
---|---|---|---|---|---|
Medium: | Tagungsbeitrag | ||||
Sprache(n): | Englisch | ||||
Tagung: | IABSE Conference: Assessment, Upgrading and Refurbishment of Infrastructures, Rotterdam, The Netherlands, 6-8 May 2013 | ||||
Veröffentlicht in: | IABSE Conference, Rotterdam, May 2013 | ||||
|
|||||
Seite(n): | 268-269 | ||||
Anzahl der Seiten (im PDF): | 8 | ||||
Jahr: | 2013 | ||||
DOI: | 10.2749/222137813806479025 | ||||
Abstrakt: |
The paper describes the studies developed for the assessment and mitigation of vibrations on a footbridge located in Portugal. The design of this steel arch footbridge with 60 m chord pointed to a lively behaviour that was investigated upon construction. The decision to install a passive control system based on two tuned mass dampers (TMDs) to mitigate vertical vibrations implied an experimental characterisation of the footbridge, the tuning of the TMDs and the verification of their efficiency, which are object of the present work. |
||||
Stichwörter: |
Schwingung von Fußgängerbrücken
|