Full Scale Load Test of A 20m Span Precast Concrete Closed Spandrel Arch Bridge System With Corrugated Section

 Full Scale Load Test of A 20m Span Precast Concrete Closed Spandrel Arch Bridge System With Corrugated Section
Autor(en): , , ,
Beitrag für IABSE Conference: Engineering the Developing World, Kuala Lumpur, Malaysia, 25-27 April 2018, veröffentlicht in , S. 933-939
DOI: 10.2749/kualalumpur.2018.0933
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.19 MB

A new form of precast concrete closed spandrel arch bridge with corrugated section was introduced and developed in Malaysia in the year of 2008. Due to its high stiffness to self-weight ratio, this...
Weiterlesen

Bibliografische Angaben

Autor(en): (School of Civil Engineering, Universiti Sains Malaysia, Penang, Malaysia)
(School of Civil Engineering, Universiti Sains Malaysia, Penang, Malaysia)
(Rivo Precast Sdn. Bhd., Klang, Selangor, Malaysia)
(Rivo Precast Sdn. Bhd., Klang, Selangor, Malaysia)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Conference: Engineering the Developing World, Kuala Lumpur, Malaysia, 25-27 April 2018
Veröffentlicht in:
Seite(n): 933-939 Anzahl der Seiten (im PDF): 7
Seite(n): 933-939
Anzahl der Seiten (im PDF): 7
DOI: 10.2749/kualalumpur.2018.0933
Abstrakt:

A new form of precast concrete closed spandrel arch bridge with corrugated section was introduced and developed in Malaysia in the year of 2008. Due to its high stiffness to self-weight ratio, this precast arch system is beneficial to the sustainable bridge construction. In order to study the actual performance of this precast arch system, a full scale load test on a 20m span arch bridge using two 88 tonnes trucks is presented in this paper. Total of five types of truck arrangement were carried out. Vertical deflection at mid span and foundation settlement were measured. It is found that the maximum vertical deflection recorded under 2 x 88 tons trucks was 3.67mm, corresponding to 1/5450 (deflection/span) ratio and there was no noticeable settlement of foundation. Analysis model load test is done using 2D analysis model PLAXIS. The results were compared to the designed analysis model with HB-45 unit loading. It is found that the internal forces of the load test are closed to the designed loading. However, the deflection in the load test analysis model is higher than actual measured deflection, probably due to the assumed value of soil modulus of elasticity and concrete modulus of elasticity. In order to approximate the deflection in the load test analysis model to the actual measured deflection, a series of sensitivity analysis on different soil young modulus and concrete young modulus were carried out.