0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Experimental study on the cooperative slip/bearing limit state of high-strength bolted frictional girder connection

 Experimental study on the cooperative slip/bearing limit state of high-strength bolted frictional girder connection
Autor(en): , ,
Beitrag für IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022, veröffentlicht in , S. 189-195
DOI: 10.2749/prague.2022.0189
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.21 MB

Bolted girder connections resist applied bending moment through the cooperation of flange and web resistances. To utilize the bending plastic capacity of the girder connection at the ultimate limit...
Weiterlesen

Bibliografische Angaben

Autor(en): (Osaka City University, Osaka, Japan)
(Osaka City University, Osaka, Japan)
(Hanshin Expressway Co. Ltd., Osaka, Japan)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022
Veröffentlicht in:
Seite(n): 189-195 Anzahl der Seiten (im PDF): 7
Seite(n): 189-195
Anzahl der Seiten (im PDF): 7
DOI: 10.2749/prague.2022.0189
Abstrakt:

Bolted girder connections resist applied bending moment through the cooperation of flange and web resistances. To utilize the bending plastic capacity of the girder connection at the ultimate limit state, the bearing capacity of the girder connection should be defined by the cooperative resistance and the ductility of bolt hole deformation. In the present study, pure bending test of plate girders bolted connection has been conducted to evaluate quantitatively the resistance and the ductility of the connection. From obtained results, it was found that the overall slip would not occur until the bolt group in the web other than around the neutral axis reaches their slip strength. In addition, overall slip strength formula with a 5% discrepancy from the experimental results has been newly proposed. As for the deformation capacity, it was found that the flange bolt hole deformation was about 10% of the bolt diameter at the design full plastic moment.

Copyright: © 2022 International Association for Bridge and Structural Engineering (IABSE)
Lizenz:

Die Urheberrechte (Copyright) für dieses Werk sind rechtlich geschützt. Es darf nicht ohne die Zustimmung des Autors/der Autorin oder Rechteinhabers/-in weiter benutzt werden.