0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Experimental analysis of steel panel dampers in replaceable coupling beams

 Experimental analysis of steel panel dampers in replaceable coupling beams
Autor(en): ,
Beitrag für IABSE Conference: Structural Engineering: Providing Solutions to Global Challenges, Geneva, Switzerland, September 2015, veröffentlicht in , S. 1733-1739
DOI: 10.2749/222137815818359195
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.09 MB

This paper introduces the theory and design method of replaceable coupling beams on the basis of a real engineering project including five 29-storey residential buildings. Based on the original str...
Weiterlesen

Bibliografische Angaben

Autor(en): (State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University, Shanghai 200092, P. R. China)
(State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University, Shanghai 200092, P. R. China)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Conference: Structural Engineering: Providing Solutions to Global Challenges, Geneva, Switzerland, September 2015
Veröffentlicht in:
Seite(n): 1733-1739 Anzahl der Seiten (im PDF): 7
Seite(n): 1733-1739
Anzahl der Seiten (im PDF): 7
Jahr: 2015
DOI: 10.2749/222137815818359195
Abstrakt:

This paper introduces the theory and design method of replaceable coupling beams on the basis of a real engineering project including five 29-storey residential buildings. Based on the original structure, several configurations of the replaceable dampers located in the center part of the replaceable coupling beams were designed. To study their inelastic seismic performance, full-scale low-cyclic loading tests were conducted in State Key Laboratory of Disaster Reduction in Civil Engineering at Tongji University, while finite element models were built using the general finite element program ABAQUS. The results of the experiments and analysis demonstrate the excellent energy dissipation capacities of the replaceable devices. Good correlations were achieved between the analytical and experimental results of the energy dissipation devices.

Stichwörter:
Hochhaus Energiedissipation