Dynamic response of bridge system with knocking-off members
|
Bibliografische Angaben
Autor(en): |
Masahide Matsumura
Masahiko Yoshida Nobuhito Ochi |
||||
---|---|---|---|---|---|
Medium: | Tagungsbeitrag | ||||
Sprache(n): | Englisch | ||||
Tagung: | IABSE Symposium: Large Structures and Infrastructures for Environmentally Constrained and Urbanised Areas, Venice, Italy, 22-24 September 2010 | ||||
Veröffentlicht in: | IABSE Symposium Venice 2010 | ||||
|
|||||
Seite(n): | 344-345 | ||||
Anzahl der Seiten (im PDF): | 8 | ||||
Jahr: | 2010 | ||||
DOI: | 10.2749/222137810796024781 | ||||
Abstrakt: |
Displacement restrainer, restraints transverse movement of the superstructure of the isolated bridges, is adopted to protect expansion joints from damage during earthquake. Here to mitigate damage of bridge pier and/or its foundation and to enhance redundancy of the isolated viaducts in a strong earthquake, it can be considered that the displacement of the superstructure against a small and moderate earthquake is restraint and the displacement against a strong earthquake is freed to shift to isolated condition. Knock-off members will provide these responses of the vibration system. This study presents the outline of some of displacement restrainers having the knock-off function and reveals the effectiveness of the knock-off in the isolated bridge system through dynamic loading test using small-size shaking table. It is also analytically verified the influences of the breaking characteristics on seismic response of the system. |
||||
Stichwörter: |
Viadukt
|