Development of a New Seismic Retrofit Method Reinforcing only Two-sides of RC Bridge Pier with Bar Cut-off Sections
|
Bibliografische Angaben
Autor(en): |
Taichiro Watanabe
(East Japan Railway Company, Tokyo, JAPAN)
Kaoru Kobayashi (East Japan Railway Company, Tokyo, JAPAN) Takahiro Kanno (East Japan Railway Company, Tokyo, JAPAN) Shigehiko Saito (University of Yamanashi, Kofu, JAPAN) |
||||
---|---|---|---|---|---|
Medium: | Tagungsbeitrag | ||||
Sprache(n): | Englisch | ||||
Tagung: | IABSE Conference: Structural Engineering: Providing Solutions to Global Challenges, Geneva, Switzerland, September 2015 | ||||
Veröffentlicht in: | IABSE Conference Geneva 2015 | ||||
|
|||||
Seite(n): | 1789-1796 | ||||
Anzahl der Seiten (im PDF): | 8 | ||||
Jahr: | 2015 | ||||
DOI: | 10.2749/222137815818359258 | ||||
Abstrakt: |
The new seismic retrofitting method in which reinforcing members were placed only on two-sides of pier structure in order to improve bending moment capacity at termination of main reinforcements was developed, which enables to avoid replacement of machine room under viaduct. In this paper, beam tests were carried out and it was clarified that bending moment carried by reinforcing members were proportional to flexural rigidity of reinforcing members and reinforced length within shear span. Then cyclic loading tests for model specimen of existing pier structures were carried out and it was also clarified that bending moment capacity at longitudinal bar cut-off points in which moment capacity are smaller than base of the pier could be improved by proposed retrofitting method and damage at the cut-off points can be avoided under seismic loading. |