Deterioration of connections and failure of light-weight façade envelopes due to sequence of seismic and wind actions

 Deterioration of connections and failure of light-weight façade envelopes due to sequence of seismic and wind actions
Autor(en): , ,
Beitrag für IABSE Congress: Challenges in Design and Construction of an Innovative and Sustainable Built Environment, Stockholm, Sweden, 21-23 September 2016, veröffentlicht in , S. 878-883
DOI: 10.2749/stockholm.2016.0865
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.19 MB

Insulated sandwich panel walls are typically screw-connected to their supporting substructure and therefore enforced to follow the displacements of the primary structure imposed by wind and seismic...
Weiterlesen

Bibliografische Angaben

Autor(en): (University of Architecture, Civil Engineering and Geodesy, Sofia, Bulgaria)
(University of Architecture, Civil Engineering and Geodesy, Sofia, Bulgaria)
(University of Architecture, Civil Engineering and Geodesy, Sofia, Bulgaria)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Congress: Challenges in Design and Construction of an Innovative and Sustainable Built Environment, Stockholm, Sweden, 21-23 September 2016
Veröffentlicht in:
Seite(n): 878-883 Anzahl der Seiten (im PDF): 6
Seite(n): 878-883
Anzahl der Seiten (im PDF): 6
Jahr: 2016
DOI: 10.2749/stockholm.2016.0865
Abstrakt:

Insulated sandwich panel walls are typically screw-connected to their supporting substructure and therefore enforced to follow the displacements of the primary structure imposed by wind and seismic actions. The paper presents an investigation of the façade envelope of a warehouse building which was slightly damaged by a recent earthquake and underwent partial failure during a wind storm a few years later. Of particular concern are the corner zones of tall single-storey buildings with stiffness irregularity in plan where the interstorey drifts produced by relatively weak earthquakes could trigger deterioration of the panel fastenings and increase their vulnerability to subsequent wind suction effects. When concealed (hidden) fastenings are used the designer should take measures either to reduce the shear and tension demands on the fastenings or to increase their capacity, e.g. through application of load distributing plates.

Stichwörter:
Schaden Tragwerksversagen