0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Bending test of a composite steel-timber beam jointed by bolts

 Bending test of a composite steel-timber beam jointed by bolts
Autor(en): , ,
Beitrag für IABSE Symposium: Towards a Resilient Built Environment Risk and Asset Management, Guimarães, Portugal, 27-29 March 2019, veröffentlicht in , S. 284-289
DOI: 10.2749/guimaraes.2019.0284
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.69 MB

In light of global environment issues, the authors proposed a building system comprising steel and timber structure (Hereafter referred to as CSTS), which consist of rolled-H section steel and timb...
Weiterlesen

Bibliografische Angaben

Autor(en): (Prof., Dr. Eng., Kanagawa University, Yokohama, Japan)
(Former Graduate student, Yamaguchi University, Ube, Japan)
(Prof. Emeritus, Dr. Eng., Kanagawa University, Yokohama, Japan)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Symposium: Towards a Resilient Built Environment Risk and Asset Management, Guimarães, Portugal, 27-29 March 2019
Veröffentlicht in:
Seite(n): 284-289 Anzahl der Seiten (im PDF): 6
Seite(n): 284-289
Anzahl der Seiten (im PDF): 6
DOI: 10.2749/guimaraes.2019.0284
Abstrakt:

In light of global environment issues, the authors proposed a building system comprising steel and timber structure (Hereafter referred to as CSTS), which consist of rolled-H section steel and timber. The CSTS is assumed to adapt for mid-rise story building steel structures. It is a design method of the CSTS that uses the concept of a damage-controlled structure characterized by using buckling-restrained braces as a seismic response control member. It is assumed to use materials such as a cross laminated timber(CLT) for floor structure of the CSTS. The hysteresis model of the CSTS is established based on the available experimental data. Assuming practicality, bending test of the composite steel-timber beam members jointed by bolts is conducted. Behaviour of the composite steel-timber beam members affected by different intervals of bolted joints is evaluated.

Stichwörter:
Stahl Verbundkonstruktion