Application of Damped Outriggers in Renovation of Super Tall Building Structures
|
Bibliografische Angaben
Autor(en): |
Daohang Hu
(Department of Structural Engineering, Tongji University, Shanghai 200092, China)
Xin Zhao (Department of Structural Engineering, Tongji University, Shanghai 200092, China Tongji Architectural Design (Group) Co., Ltd, Shanghai 200092, China) |
||||
---|---|---|---|---|---|
Medium: | Tagungsbeitrag | ||||
Sprache(n): | Englisch | ||||
Tagung: | IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022 | ||||
Veröffentlicht in: | IABSE Symposium Prague 2022 | ||||
|
|||||
Seite(n): | 1844-1850 | ||||
Anzahl der Seiten (im PDF): | 7 | ||||
DOI: | 10.2749/prague.2022.1844 | ||||
Abstrakt: |
The primary task of super tall buildings renovation is to reduce the engineering amount for existing structures. The additional viscous damping device can effectively increase the structural energy consumption of super tall buildings under earthquakes, thereby reducing the internal force and deformation response of the structure, and achieving the purpose that reduce the amount of renovation works. Assembling the deformation amplification device can effectively improve the energy consumption capacity of the viscous damping device. There are two damping types of deformation amplification for super tall buildings: toggle brace dampers and damped outriggers. Toggle brace dampers is suitable for high-rise building structures with shearing deformation, and damped outriggers is suitable for high-rise building structures with bending deformation. Based on the actual engineering case, this paper studies the viscous damper (damped outriggers) with outrigger deformation amplification device. Firstly, the sensitivity of installing damped outriggers on different equipment floors is analyzed, and the influence of different installation positions on the efficiency of damped outriggers is determined. Secondly, the reasonable number of damped outriggers is studied to effectively reduce the reconstruction work of the existing structure and control the number and parameters of viscous dampers in a reasonable range. Finally, the influence of the damped outrigger on the structural response of the unbuilt part is analyzed, and how to further optimize the structural members of the unbuilt part is studied. |
||||
Copyright: | © 2022 International Association for Bridge and Structural Engineering (IABSE) | ||||
Lizenz: | Die Urheberrechte (Copyright) für dieses Werk sind rechtlich geschützt. Es darf nicht ohne die Zustimmung des Autors/der Autorin oder Rechteinhabers/-in weiter benutzt werden. |