Adaptive TMD System for Reduced Space Demand in Tall Buildings

 Adaptive TMD System for Reduced Space Demand in Tall Buildings
Autor(en): , , , ,
Beitrag für IABSE Congress: The Evolving Metropolis, New York, NY, USA, 4-6 September 2019, veröffentlicht in , S. 377-383
DOI: 10.2749/newyork.2019.0377
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.26 MB

Tuned mass dampers (TMDs) are widely used to mitigate wind-induced tall building vibrations. However, two major disadvantages of passive TMDs exist. The installation height of pendulum TMDs consume...
Weiterlesen

Bibliografische Angaben

Autor(en): (Maurer Switzerland GmbH)
(Maurer SE)
(Maurer SE)
(Maurer SE)
(Maurer Engineering GmbH)
(Maurer SE)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Congress: The Evolving Metropolis, New York, NY, USA, 4-6 September 2019
Veröffentlicht in:
Seite(n): 377-383 Anzahl der Seiten (im PDF): 6
Seite(n): 377-383
Anzahl der Seiten (im PDF): 6
DOI: 10.2749/newyork.2019.0377
Abstrakt:

Tuned mass dampers (TMDs) are widely used to mitigate wind-induced tall building vibrations. However, two major disadvantages of passive TMDs exist. The installation height of pendulum TMDs consumes expensive space and passive TMDs cannot cope with the time-varying excitation frequency of wind loading which will excite several structural modes. Also, the pendulum mass may impact the structure due to seismic excitation which necessitates huge snubbing systems. The presented adaptive TMD System addresses all these shortcomings. The installation height is reduced by up to 50 % by the inclination of the pendulum cables as this method enlarges the radius of the pendulum mass center being equivalent to the reduction of the natural pendulum frequency. The efficiency of the adaptive TMD is improved by adjusting the oil damper characteristics in real-time which allows reducing the pendulum mass up to 20 %. The overdamping control approach activated at wind return periods greater than 10 years reduces the maximum pendulum relative motion by up to 25 %. The adaptive TMD with inclined cables therefore minimizes the installation space which helps to maximize the economic benefit of the building.

Stichwörter:
Dämpfung

Bauwerke und Projekte